Page 10-1036PR-MAINT (Maintenance Processor [TN790 RISC Systems]) 
10
Notes:
a. The MTP Reset Test (#101) has failed.
b. The MTP Sanity Handshake Test (#106) has failed.
c. The MTP Analog Loop Around Test (#103) has failed.
d. The MTP Dual Port Ram Test (#104) has failed. An error of 769 with an aux 
data of 5 indicates a hardware problem and testing cannot clear it. 
Replace the circuit pack. 
e. The MTP Outpulse Relay Test (#102) has failed.
f. The MTP SAT Loop Around Test (#228) has failed.
g. The MTP Aux Loop Around Test (#229) has failed.
h. The External Modem Present Test (#230) has failed.
NOTE:
Refer to the FAIL section of each test that fails for further instructions.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing 
error codes associated with the 
MTP Reset Test,
 for example, you may also clear 
errors generated from other tests in the testing sequence. The following table is 
for the TN790 [RISC] System.
1. The MTP Reset Test (#101) logs you off. The MTP Dual Port Ram Test (#104) can also log you off. 
Manually repeat the command with the ‘‘long’’ option for the designated number of times when 
testing from the PPN SAT.
2. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
1537(f) Any MTP SAT Loop Around Test 
(#228)
MIN ON test processor a/b r 3
1793(g) Any MTP Aux Loop Around Test 
(#229)
MIN ON test processor a/b r 3
2049(h) Any External Modem Present 
Test (#230)
MIN OFF test processor a/b r 2
Table 10-353. PR-MAINT Error Log Entries  — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
1
Continued on next page