User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-996PKT-CTRL (Packet Control Circuit Pack) 
10
c. This error indicates that a loss of communication was detected between 
the SPE software and the Packet Control circuit pack. No alarm is raised. 
However, if this error occurs repeatedly, software testing escalates to the 
Reset Test (#586) so that the health of the Packet Control circuit pack can 
be determined.
d. This error occurs when the Packet Control Loop Around Test (#585) fails 
because a link cannot be established or because the Packet Control 
circuit pack cannot send and receive data correctly. No alarm is raised. 
However, if this error occurs repeatedly, software testing escalates to the 
Reset Test (#586) so that the health of the Packet Control circuit pack can 
be determined.
e. This error occurs when the Packet Control Parity Circuitry Test (#584) fails, 
thus indicating a possible fault with the parity circuitry in detecting Packet 
Bus parity errors. If this error occurs a number of times exceeding a 
defined threshold, a minor on-board alarm is raised.
f. This error occurs when a certain circuit pack-level diagnostic test fails, 
thus indicating a transient fault (which has been recovered) existed on the 
Packet Control/Packet Bus interface. No alarm is raised because the error 
does not isolate the fault to the Packet Control circuit pack. However, if the 
error occurs repeatedly, software testing escalates to the Reset Test 
(#586) so that the health of the Packet Control circuit pack can be 
determined.
g. This error occurs when a certain circuit pack-level diagnostic test fails, 
indicating there is a fault on the Packet Control/Packet Bus interface. No 
alarm is raised because the Packet Bus may be the source of problem. 
When this error occurs, Packet Bus maintenance is notified, thereby 
causing appropriate tests to run.
h. This error occurs when a parity error is detected by the Packet Control 
circuit pack, indicating some data sent over the Packet Bus is corrupted. 
No alarm is raised against the Packet Control circuit pack because the 
problem may be associated with the Packet Bus. When this error occurs, 
Packet Bus maintenance is notified, thereby causing appropriate tests to 
run.
i. This error occurs when the Packet Control circuit pack receives a 
threshold number of frames with invalid address. No alarm is raised 
because there is no direct indication of a Packet Control fault. The frames 
may be corrupted by the sending side or by the Packet Bus. No 
maintenance activity is triggered by this error. No action is required.
j. This error occurs when the Packet Control Download Test (#581) fails. 
Once a threshold number of these errors occur, a major off-board alarm is 
raised. Maintenance software retries the download test repeatedly until it 
passes. Since the reset packet-control C command causes the firmware 
to be downloaded and provides additional diagnostics on this error type, 