Maintenance Object Repair Procedures 
Page 10-990PKT-BUS (Packet Bus) 
10
1142 ABORT No Maintenance/Test circuit pack Packet Bus port is in service in this port 
network.
1. If this system has High or Critical Reliability, either (a) the 
Maintenance/Test circuit pack for this port network has failed, and should 
be replaced, (b) the Maintenance/Test circuit pack has been busied out, 
and should be released, or (c) there is no Maintenance/Test circuit pack 
in this port network, and one must be installed.
2. In a system without High or Critical Reliability, the Maintenance/Test 
Packet Bus Port may not be present. If the port is present, and if it is 
busied out or has failed, release or replace the circuit pack. If there is no 
Maintenance/Test circuit pack, ignore the results of this test for this port 
network.
2000 ABORT The test timed-out while waiting for an uplink CCMS response from the 
Maintenance/Test Packet Bus port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, check for problems with the 
Maintenance/Test Packet Bus port .
2059 ABORT The Maintenance/Test Packet Bus port has reported a hardware failure.
1. Re-enter the test command.
2077 ABORT The Maintenance/Test Circuit Pack Query located more than one 
Maintenance/Test Packet Bus port in the port network.
NOTE:
The software should not allow this to occur. This is an Internal system 
error. Attempt the following work-around steps.
1. Remove all Maintenance/Test circuit packs from the port network.
2. Insert one Maintenance/Test circuit pack (there should not be more than 
one in a port network).
3. Re-enter the test command.
2100 ABORT Maintenance could not allocate all of the necessary system resources to 
perform this test.
2500 ABORT An internal operation failed; the test could not be completed.
1. Retry the command at 1-minute intervals a maximum of 5 times.
XYZZ FAIL The Maintenance/Test Packet Bus port has detected faults on the Packet Bus. 
The error code is encoded as follows:
1xxx The Maintenance/Test Packet Bus port has reconfigured the Packet Bus 
around the faulty leads. This occurs only in high or critical reliability systems.
Table 10-336. TEST #572 Maintenance/Test Circuit Pack Query Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page