Maintenance Object Repair Procedures 
Page 10-936PE-BCHL (PRI Endpoint Port) 
10
b. This is a software audit error that does not indicate any hardware 
malfunction. Run the Short Test Sequence and investigate the associated 
errors (if any).
c. The PRI Endpoint Port has been busied out by a busyout pri-endpoint 
<extension> command or by a busyout port <PCSSpp> command. No 
wideband calls can be made to this port (although wideband calls can still 
be made to other ports within this PRI Endpoint if others ports are in 
service).
d. The far-end terminal adapter changed its ISDN 
service
 state to either 
"out-of-service" or "maintenance." This may be a temporary condition due 
to the testing of this port by the far-end terminal adapter 
or
 by a hardware 
problem with the port. Outgoing calls to the terminal adapter are not 
allowed over the port (although calls can still be made to other ports that 
are in service within the same PRI Endpoint). To investigate the status of 
the port, issue the status pri-endpoint <extension> command.
e. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
f. This error type indicates a disagreement between this switch and the 
terminal adapter at the other end of the connection with regard to the 
ISDN service state of the PRI Endpoint Port. This switch tries to recover by 
performing a service state audit. The status pri-endpoint <extension> 
command can be used to determine the state of the port.
When running the Short Test Sequence, pay close attention to the results 
of the Service State Audit Test (#256).
g. This port is not recognized by the far-end terminal adapter. Investigate the 
PRI Endpoint administration for both the switch and the terminal adapter 
and make changes as necessary.
h. The Conference Circuit Test (#7) failed on this port. See Test #7 for the 
repair procedures.
i. The NPE Crosstalk Test (#6) failed on this port. See Test #6 for the repair 
procedures.
j. This error indicates a failure of the UDS1 Interface circuit pack. When 
running the Short Test Sequence, the results of the Signaling Link State 
Check Test (#255) are important.
k. Two Service State Audit attempts have failed (see Test #256). The port is 
not usable for any outgoing calls to the terminal adapter (although 
incoming calls from the terminal adapter are accepted over this port, other 
ports in the PRI Endpoint can still be used for both incoming and outgoing 
calls to and from the terminal adapter) until the test passes and the port 
state is changed to in-service (use the status pri-endpoint <extension> 
command to investigate the port status).