DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-887M/T-DIG (Maintenance/Test Digital Port) [G3iV1-1.286, G3iV2-386] 
10
Hook State Inquiry (#566)
This test ensures that the Maintenance/Test Digital Port maintenance software 
and call processing agree on the on-/off-hook status of the Maintenance/Test 
Digital Port.
1138 ABORT This test does not run on Port 3 of the Maintenance/Test circuit pack. 
This test runs only on Port 2. Look at the results of the Digital Port Sanity 
Test for Port 2.
1. Run the command again for Port 2 via the test port PCSS02 or test 
port PCSS02 l command.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required to run this test are not available.
2500 ABORT An internal operation failed; the test could not be completed.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to fail, escalate the problem.
50 FAIL The switch was unable to communicate with the port circuitry used for 
digital trunk testing.
100 FAIL Data was not sent from Port 2 to Port 3 successfully in asynchronous 
mode.
101 FAIL Data was not sent from Port 3 to Port 2 successfully in asynchronous 
mode.
102 FAIL Data was not sent from Port 2 to Port 3 successfully in synchronous 
mode.
103 FAIL Data was not sent from Port 3 to Port 2 successfully in synchronous 
mode.
1. Reset the circuit pack via the busyout board PCSS, reset board 
PCSS, release board PCSS command sequence.
2. Test the port again via the test port PCSS02 l command.
3. If the test fails again, replace the circuit pack.
PASS The Maintenance/Test Digital Port digital trunk testing capability is 
operating correctly.
Table 10-299. TEST #161 Loop Around Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page