Maintenance Object Repair Procedures 
Page 10-839MODEM-PT (Modem Pool Port) 
10
Modem Pool Conversion Resource Loop Around 
Test (#98)
The Modem Pool Conversion Resource Loop Around Test is set up as follows:
65515 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. Issue the test port long command on the port on which the test 
aborted. If any test aborted or failed, follow recommended 
maintenance strategy for the appropriate port type (for example, 
ANL-LINE, DIG-LINE).
3. If the test continues to abort, escalate the problem.
NONE FAIL The test failed. This error is internal to the Pooled Modem circuit pack 
and does not involve external equipment or interfaces.
1. Busyout both of the TN758 Pooled Modem conversion resources on 
the circuit pack containing the failing conversion resource.
2. If the test continues to fail, replace the Pooled Modem circuit pack 
and retest.
3. If the circuit pack fails after replacement, escalate the problem.
ANY FAIL The Network Processing Element (NPE) of the tested port did not 
conference the tones correctly. This causes noisy and unreliable 
connections.
1. If the remaining ports are currently not in use (that is, yellow LED is 
off), attempt to reset the circuit pack. Then repeat the test.
2. If the test fails again, replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported 
troubles on this port should be investigated using other port tests and 
by examining station, trunk, or external wiring.
Table 10-279. TEST #97 Modem Pool Conference Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page