Page 10-817MET-LINE (MET Line) 
10
1003 ABORT The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of Tone Detectors present or some 
Tone Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to 
TTR-LEV (TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to 
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test has been 
aborted. Use the display port PCSSpp command to determine the 
station extension, attendant number, or trunk group/member number of 
the port. Use the status station, status attendant, or status trunk 
command to determine the service state of the port. If the service state 
indicates that the port is in use, then the port is unavailable for certain 
tests. (Refer to the "Status Commands" section in Chapter 8, 
‘‘Maintenance Commands and Trouble-Clearing Aids’’ for a full 
description of all possible states.) You must wait until the port is idle 
before retesting. Attendants are always in use (off-hook) if the handset 
is plugged in and the port is not busied out.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to abort and the port is not in use, escalate the 
problem.
2000 ABORT Response to the test request was not received within the allowable time 
period.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to abort, escalate the problem.
2012 ABORT Internal System Error.
2103 ABORT The system could not make the conference connection for the test.
1. Retry the command at one-minute intervals a maximum of five 
times.
2. If the test continues to abort, escalate the problem.
Table 10-274. TEST #57 MET Circuit and Conference Circuit Test — Continued
Error 
Code
Test 
Result Description/ Recommendation