User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-770ISDN-TRK (DS1 ISDN Trunk) 
10
2212 ABORT Call terminated by unexpected disconnect.
1. Wait 1 minute and then try again.
2213 ABORT The call has timed-out, perhaps because of a lack of system resources.
1. Follow the recommendations for ABORT code 2035.
2214 ABORT Call terminated by unexpected disconnect.
1. Wait 1 minute and then try again.
2215 
2216 
2217 
2218 
2219
ABORT Internal system error
1. Follow recommendations for ABORT code 2012.
2220 ABORT Call terminated prematurely.
1. Wait 1 minute and try again.
2221 
2222 
2223 
2224 
2225 
2226
ABORT Internal system error
1. Follow recommendations for ABORT code 2012.
2227 ABORT Could not allocate the necessary system resources to run this test.
1. Follow the recommendations for ABORT code 2100.
2042 FAIL This is the main purpose of the test. The comparison of the data sent 
with the data received indicates a loss of integrity on the communications 
path.
1. The trunk should be taken out-of-service and the quality of the DS1 line 
should be investigated. The investigation should include an in-depth 
analysis of the DS1 facility including the transmission facility and any 
external equipment such as DACs, CSUs, etc. If the test isdn-testcall 
command is invoked, then the investigation should include getting the 
bit and block error rates by invoking the status isdn-testcall 
command.
Table 10-256. TEST #258 ISDN TEST Call — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page