User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-732ISDN-SGR (ISDN-PRI Signaling Group) 
10
There is no test to clear these errors. The error counter is decremented by 
1 every 15 minutes.
b. This error indicates that the primary signaling channel connection has 
been lost for more than 90 seconds. If a secondary signaling channel 
does not exist or is not in-service, the associated B-channels will be 
placed in the ISDN Maintenance/Far-End state. The B-channels will not be 
usable for outgoing calls, although incoming calls will still be accepted. 
The switch will automatically attempt to recover the signaling link. Pay 
particular attention to the results of Test #636 (Primary Signaling Link 
Hardware Check) in the test sequence. When the link does recover, the 
B-channels will be negotiated back to the In-Service state and their alarms 
will be retired.
When this error occurs, the state of the Signaling Group is changed to 
out-of-service (verify using the status sig-group command).
c. This error indicates that the secondary signaling channel connection has 
been lost for more than 90 seconds. If the primary signaling channel is not 
in-service, B-channels will be placed in the ISDN Maintenance/Far-End 
state. The B-channels will not be usable for outgoing calls, although 
incoming calls will still be accepted. The switch will automatically attempt 
to recover the signaling link. Pay particular attention to the results of Test 
#639 (Secondary Signaling Link Hardware Check) in the test sequence. 
When the link does recover, the B-channels will be negotiated back to the 
In-Service state and their alarms will be retired.
When this error occurs, the state of the Signaling Group is changed to 
out-of-service (verify using the status sig-group command).
d. This error indicates a failure of the Layer 2 Status Query Test for the 
primary signaling channel
e. This error indicates a failure of the Layer 2 Status Query Test for the 
secondary signaling channel.
f. A specific message was sent to the far-end switch, and it did not respond 
within the allotted time. Investigate elements of the ISDN PRI D-channel(s) 
(ISDN-LNK, ISDN-PLK, ISDN-SGRP, PI-LINK, PI-PT, PKT-CTRL) for both 
this switch and the Far-end switch. If Test #637 fails twice in a row, the 
B-channels will be alarmed and made unavailable for outgoing calls 
(although incoming calls will still be accepted). When Test #637 succeeds 
and the Far-end switch starts responding properly, the DS1 ISDN Trunk 
(B-channels) will be placed back into normal operation and their alarms 
will be retired.
g. A SERV or SERV ACK ISDN D-channel message has been received by a 
non-US-type interface (country option other than 1 on the DS1 
administration form). However, these messages are used only for duplex 
NFAS signaling which is supported only by country protocol 1.
Thus, there may be a mismatch in administration between the local and 
far-end switches. Consult with the customer’s network provider to 
determine whether the D-channel is set up correctly on the far-end switch.