User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-688HYB-LINE (Hybrid Line) 
10
1000 ABORT System resources required to run this test are not available. The port may 
be busy with a valid call. Use the display port PCSSpp command to 
determine the station extension number of the port. Use the status station 
command to determine the service state of the port. If the service state 
indicates that the port is in use, then the port is unavailable for certain 
tests. (Refer to the "Status Commands" section in Chapter 10, 
"Maintenance Commands and Trouble-Clearing Aids" for a full description 
of all possible states.) You must wait until the port is idle before retesting. 
Attendants are always in use (off-hook) if the handset is plugged in and the 
port is not busied out.
1. If the port status is idle, then retry the command at one-minute 
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a valid call during the test. The test has been 
aborted. Use the display port PCSSpp command to determine the station 
extension number of the port. Use the status station command to 
determine the service state of the port. If the service state indicates that the 
port is in use, then the port is unavailable for certain tests. (Refer to the 
"Status Commands" section in Chapter 10, "Maintenance Commands and 
Trouble-Clearing Aids" for a full description of all possible states.) You 
must wait until the port is idle before retesting. Attendants are always in 
use (off-hook) if the handset is plugged in and the port is not busied out.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort and the port is not in use, escalate the 
problem.
2000 ABORT Response to the test request was not received within the allowable time 
period.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-229. TEST #58 Hybrid Line Local Digital Loop Around Test  — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page