Page 10-684HYB-LINE (Hybrid Line) 
10
Table 10-228. TEST #57 Hybrid Circuit and Conference Circuit Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may 
be busy with a valid call. Use the display port PCSSpp command to 
determine the station extension number of the port. Use the status station 
command to determine the service state of the port. If the service state 
indicates that the port is in use, then the port is unavailable for certain 
tests. (Refer to the "Status Commands" section in Chapter 10, 
"Maintenance Commands and Trouble-Clearing Aids" for a full description 
of all possible states.) You must wait until the port is idle before retesting. 
Attendants are always in use (off-hook) if the handset is plugged in and the 
port is not busied out.
1. If the port status is idle, then retry the command at one-minute 
intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1001 ABORT Could not allocate the necessary system resources to run this test. This 
could be due to a failure to seize the port.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance 
documentation to diagnose any active TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV 
(TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT 
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
Continued on next page