Maintenance Object Repair Procedures 
Page 10-677HYB-LINE (Hybrid Line) 
10
a. Indicates a defective data link. An off-board problem was detected by 
port circuit. Verify that the Hybrid set is connected and that the EPF test 
passes. If data transmission problems are experienced, check for 
defective wiring or a defective voice terminal, or move terminal closer to 
the switch (in terms of feet of wire from the jack to the switch). If the 
problem still exists, replace the circuit pack. Once the problem has been 
resolved, the alarm is retired after a predetermined period of time.
b. This is a software audit error that does not indicate any hardware 
malfunction. Run Short Test Sequence and investigate associated errors 
(if any).
c. This error type is logged when the port in question is busied out by 
maintenance personnel. Make sure port is released from busyout via the 
release port PCSSpp command.
d. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or 
replace the circuit pack.
e. This indicates that the EPF has been turned off due to an overcurrent 
condition at the voice terminal. Check for defective wiring or a damaged 
jack, and make sure the voice terminal is a Hybrid set. Once the problem 
has been resolved, the alarm is retired after a predetermined period of 
time.
f. This indicates that the voice terminal has probably been disconnected or 
that there is a problem in the wiring to the terminal. Make sure that the 
voice terminal is connected or check for defective wiring to the voice 
terminal.
g. Note that Error Types 769 and 1281 by themselves create Warning alarms 
only, but if both are present, a Minor alarm is logged.
h. This indicates that there is something wrong with the data link to the voice 
terminal. An in-line maintenance error has generated an off-board 
warning. Ignore it if there are no complaints. Otherwise, make sure the 
voice terminal is connected, check for defective wiring, check for a 
defective voice terminal, and move voice terminal closer to the switch (in 
terms of feet of wire from the jack to the switch). If the problem still exists, 
replace the circuit pack.
i. This indicates that the station went off-hook while in the disconnect state. 
Use the status station command to determine the state of the station. The 
off-hook should have moved the station to in-service. No system 
technician action is necessary.
j. This is the code that is generated when the link between the circuit pack 
and the voice terminal is successfully reset. No system technician action 
is necessary.