User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-674HYB-LINE (Hybrid Line) 
10
HYB-LINE (Hybrid Line)
Hybrid Line is the user-friendly name for Hybrid Line, which was previously used 
to denote the Multifunction Analog Telephone. The Hybrid Line set is also known 
as an SCS (Small Communications System).
The TN762B Hybrid Line circuit pack supports eight of these multifunction 
analog telephone sets, as shown in the following figure. The Hybrid Line sets use 
three pairs of wires: an analog voice pair, a transmit/receive pair, and a power 
pair.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ..., etc.); and pp is the 2-digit 
port number (for example, 01).
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
Full Name of MO
HYB-LINE Minor test port PCSSpp l Hybrid Line
HYB-LINE Warning test port PCSSpp l Hybrid Line