User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-665FL-DATA (Flash Data Consistency) 
10
44 FAIL The update files, load vintages, and announcements are different in 
both SPEs. The Active SPE has the most current update file and 
announcements.
45 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current update 
file, translations, and announcements.
46 FAIL The update files, load vintages, translations, and announcements are 
different in both SPEs. The Active SPE has the most current update file 
and announcements, and the Standby SPE has the most current 
translations.
1. Follow the procedures for Error Code 4 to get the correct load 
vintage. Be sure to save the announcements. After running the 
test card-mem long command, check for Error Codes 32 or 64. 
Follow the recovery procedure under the applicable error code.
48 FAIL The update files and announcements are different in both SPEs. The 
Active SPE has the most current update file, and the Standby SPE has 
the most current announcements.
1. Follow the procedures for Error Code 40.
49 FAIL The update files, translations, and announcements are different in both 
SPEs. The Active SPE has the most current update file and 
translations, and the Standby SPE has the most current 
announcements.
50 FAIL The update files, translations, and announcements are different in both 
SPEs. The Active SPE has the most current update file, and the 
Standby SPE has the most current translations and announcements.
1. Follow the procedures for Error Code 41.
Table 10-223. TEST #421 Flash Data Consistency Check Test  — Continued
Error Code
Test 
Result Description/Recommendation
Continued on next page