Maintenance Object Repair Procedures 
Page 10-664FL-DATA (Flash Data Consistency) 
10
38 FAIL The update files, load vintages, and translations are different in both 
SPEs. The Active SPE has the most current update file, and the 
Standby SPE has the most current translations.
1. Follow the procedures for Error Code 4 to get the correct load 
vintage. After running the test card-mem long command, check 
for Error Codes 32 or 64. Follow the recovery procedure under the 
applicable error code.
40 FAIL The update files and announcements are different in both SPEs. The 
Active SPE has the most current update file and announcements.
1. Issue the save announcements command to save 
announcements on both SPEs.
2. Have INADS issue the copy update-file command to copy the 
update file from the Active to the Standby SPE.
3. Run the test card-mem long again to resolve the alarms.
41 FAIL The update files, translations, and announcements are different in both 
SPEs. The Active SPE has the most current update file, translations, 
and announcements.
42 FAIL The update files, translations, and announcements are different in both 
SPEs. The Active SPE has the most current update file and 
announcements, and the Standby SPE has the most current 
translations.
1. Issue the save translations command.
2. Issue the save announcements command.
3. Have INADS issue the copy update-file command to copy the 
update file from the Active to the Standby SPE.
4. Reissue the test card-mem long command to resolve the alarms.
Table 10-223. TEST #421 Flash Data Consistency Check Test  — Continued
Error Code
Test 
Result Description/Recommendation
Continued on next page