User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-660FL-DATA (Flash Data Consistency) 
10
Notes:
a. See “CARD-MEM” for this test description.
b. See “12V-PWR” for a description of this test.
c. The Flash Data Consistency Test does not run in a Standard system.
Flash Data Consistency Check Test (#421)
The software vintage number, translation time stamps, announcement time 
stamps, and update file time stamps and identifiers are read off of both memory 
cards or SPEs and then compared. If the comparison shows any discrepancy, 
FL-DATA is alarmed. This test is only run in a High or Critical Reliability system. 
The test is run as part of the test card-mem long and as part of the standby PE 
scheduled maintenance.
Table 10-223. TEST #421 Flash Data Consistency Check Test 
Error Code
Test 
Result Description/Recommendation
0 ABORT The test timed out without completing. This error can occur when the 
system is heavily loaded and the test is not allocated sufficient time to 
run.
1. Rerun the test when the system is less busy and is not running 
standby maintenance.
1029 1030 
2011 2012 
2013 2014 
2015 2016 
2017 2018 
2019 2020 
2021 2022 
2023 2024 
2025 2051
ABORT Refer to the STBY-SPE (Standby SPE) Maintenance documentation for 
a description of these error codes.
9005 ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
35498 ABORT Difficulty was encountered trying to send information between the 
SPEs.
35512 ABORT The Standby SPE cannot be put into maintenance mode.
1. Check for and resolve all DUPINT (Duplication Interface Circuit 
Pack), SHDW-LNK (Memory Shadowing Link), SHDW-CIR 
(Common Shadow Circuit), and STBY-SPE (Standby SPE) alarms.
2. Retry the command.
Continued on next page