User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-649EXT-DEV ADMIN? N (External Device Alarm) 
10
EXT-DEV ADMIN? N (External Device 
Alarm)
NOTE:
Use this Maintenance Object when the 
External Device Alarm Admin?
 field 
on the 
change system-parameters customer-options
 form is set to (n).
In the Standard Reliability PPN the Maintenance Processor (TN786B or TN790) in 
carrier (A) monitors the EXT-DEV alarm leads. In the High or Critical PPN, the 
Duplication Interface (TN772) circuit pack in carrier (A) monitors the EXT-DEV 
alarm leads, and provides status to the Maintenance processor (TN786B or 
TN790) in the active SPE. In the EPN the Maintenance Board (TN775) monitors 
the EXT-DEV alarm leads. The system only recognizes pairs connected to the 1M 
and 1m (ALARM MONITOR) leads. Pairs connected to the 2M, 2m, 3M, 3m, and 
3w are not recognized by the system. Refer to the 
DEFINITY Communications 
System Generic 1 and Generic 3i Wiring,
 555-204-111, for more details.
Hardware Error Log Entries and Test to Clear 
Values
1. where UU is an appropriate cabinet number determined via the PORT field from the 
Alarm or Error Log.
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
2. One port generates a MAJOR alarm; the other port generates a MINOR alarm.
MO Name (in 
Alarm Log)
Alarm 
Level Initial Command to Run
1
Full Name of MO
EXT-DEV MAJOR test environment UU  External Device Alarm
EXT-DEV MINOR test environment UU  External Device Alarm
Table 10-218. Hardware Error Log Entries and Test to Clear Values
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test environment UU r2 or 
6
1 or 5 Any External Device 
Alarm Test (#120)
MAJOR 
MINOR
2
OFF test environment UU r 2 or 
6