User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-634EXP-INTF (Expansion Interface Circuit Pack) 
10
4 ABORT Could not reset EPN Expansion Interface circuit pack over optical fiber 
since PPN Expansion Interface circuit pack on opposite end of fiber is not 
inserted.
1. Insert opposite Expansion Interface circuit pack and perform reset 
again.
1015 ABORT The system does not allow this test to be run because the Expansion 
Interface circuit pack has not been busied out.
1. Busyout the Expansion Interface circuit pack. Repeat the reset board 
PCSS command.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
9999 ABORT Expansion Interface circuit pack reset successfully. Could not perform 
initialization test results query because link to EPN is not up.
1. Execute release board PCSS. Wait one minute. Issue the display 
error command. If you see Error Type 2049 logged against this 
Expansion Interface circuit pack, then the Expansion Interface Reset 
Test has failed with an error code equal to the aux data of this entry. 
Otherwise, the initialization tests have passed.
12000 ABORT Expansion Interface circuit pack reset successfully. Response to the 
initialization test results query was not received within the allowable time 
period.
12100 ABORT Expansion Interface circuit pack reset successfully. System resources 
required to run initialization test are not available.
1. Retry the command at 1-minute intervals a maximum of 5 times.
12026 ABORT Expansion Interface circuit pack reset successfully. It responded with an 
unknown reply to the query for the results of its initialization tests.
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, replace the circuit pack or transceiver.
Table 10-215. TEST #336 Expansion Interface Reset Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page