Maintenance Object Repair Procedures 
Page 10-627EXP-INTF (Expansion Interface Circuit Pack) 
10
NOTE:
When the Expansion Interface circuit pack under test is an EPN, the data 
packet must also pass through the Active Expansion Interface circuit packs 
of the Active link connecting the EPN to the PPN.
This test requires the Expansion Interface circuit pack to ignore incoming data 
from its neighbor Expansion Interface circuit pack on the opposite end of the 
fiber. Thus, this test disturbs any inter-cabinet connections that currently exist 
and disrupts signaling between the two cabinets.
Table 10-213. TEST #242 Expansion Interface Lightwave 
Transceiver Loop Around Test 
Error 
Code
Test 
Result Description/Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals a maximum of 5 times.
1002 ABORT The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors. Refer to TDM-BUS (TDM Bus) Maintenance 
documentation to diagnose any active TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals a maximum of 5 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Hardware Error Log. If present, refer to 
TTR-LEV (TTR Level) Maintenance documentation. Even if there are no 
TTR-LEV errors, there still may not be a Tone Detector available on the 
network that contains the circuit pack being tested. Verify that there is 
at least one Tone Detector on this network. If there is not at least one 
Tone Detector, this test always aborts for this Expansion Interface 
circuit pack. This does not harm the system in any way.
2. Look for TONE-PT errors in the Hardware Error Log. If present, refer to 
TONE-PT (Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at 1-minute intervals a 
maximum of 5 times.
1015 ABORT The system does not allow this test to be run because the Expansion 
Interface circuit pack has not been busied out.
1. Busyout the Expansion Interface circuit pack. Repeat the test board 
PCSS long command.