User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Routine Maintenance Procedures 
Page 5-29Software Upgrade 
5
Save Current Translations to Original Translation 
Card
1. Set the write switch on the original translation card down to record. Insert 
the card into the slot on the TN777B faceplate. 
2. Enter save translation
 and press Enter to get translations onto the 
translation card. This takes about 5 minutes. The yellow LED on the 
TN777B is on. If the translations were corrupted, the following error 
message displays when logging in:
!
WARNING:
Translation corruption detected; call Lucent Technologies distributor 
immediately.
NOTE:
The save translation command cannot function if the translation corruption 
message appears.
Disable TTI
Enter change system-parameters features and press Enter. Use Page 2 of the 
form to disable Terminal Translation Initialization (TTI) by changing the value to n.
List Configuration Software Version
Issue the list configuration software-versions command to determine whether 
any patches have been applied.
NOTE:
If the system must be restored to the old software, download the correct 
patches back onto the system.
Disable Scheduled Maintenance
1. Enter change system-parameters maintenance, and press Enter. Use 
this form to prevent scheduled daily maintenance from interfering with the 
update or upgrade.
NOTE:
If scheduled maintenance has begun, set the value of the “Stop 
Time” field to one minute after the current time. If scheduled 
maintenance has not yet begun, change the value of the “Start Time” 
field to a time after the upgrade is finished.
Disable Alarm Origination to INADS
1. Enter change system-parameters maintenance and press Enter. 