User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-612EXP-INTF (Expansion Interface Circuit Pack) 
10
m. Error Type 3330 indicates a failure of a diagnostic component on the 
Expansion Interface circuit pack. The failed component does not impair 
service, but it may leave the EI circuit pack in a state where the EI circuit 
pack cannot detect errors.
n. Error Type 3585 indicates that the EI circuit pack experienced a series of 
very short out-of-frame conditions within several minutes. This may 
indicate transmission difficulties over the fiber link. If this is a duplex 
system, and if no other alarms exist, the system should have switched 
away from the fiber link using this EI circuit pack. If this condition ceases, 
the warning alarm should be resolved within 15 minutes. In the meantime, 
make sure all lightwave transceivers are firmly secured to the back of the 
cabinet. Thereafter, if the alarm is not resolved during the next four 
15-minute segments, replace the following (the first after the first 
15-minute segment, the second after the second 15-minute segment, and 
so forth):
1. Lightwave transceiver attached to the EI reporting the alarm
2. Lightwave transceiver on the opposite end of the fiber
3. Expansion Interface board reporting the alarm
4. Expansion Interface board on the opposite end of the fiber
Since the counter is active only due to a transient condition, there is no 
test that can be run to clear the counter. However, the counter 
automatically decrements by one every five minutes. Once the condition 
causing the transient Fibers Out-of-Frame (FOOFs) has been fixed, it will 
take 15 minutes for the counter to be cleared if the alarm was raised.
o. Error Type 3841 indicates that the EI (TN570 only) has reported a loss of 
lock with the backplane system clock.
p. Error Type 3842 indicates that the test that queries the EI (TN570 only) for 
the state of the lock to the system clock has failed. This means that a loss 
of lock condition is present. A link switch is then attempted, and the alarm 
is raised. When both links report this error, the link switch is not attempted 
because, in this case, the problem is more likely to occur with the 
backplane clock than with the Expansion Interface circuit pack.
q. The counter associated with Error Types 3841 and 3842 is cleared when 
the query for the state of the lock-to-system-clock passes. Once the alarm 
is raised, this test is run every five minutes. However, the test is not part of 
any sequence that can be run on demand.
r. Error Type 10000 is a report from the EI circuit pack that its internal data 
has become corrupted. The EI circuit pack has lost track of control 
messages destined for the EPN. When this error is detected, the system 
automatically resets the EI circuit pack and brings the EPN down. Service 
to the EPN is unavailable for several minutes after detection of this error. 
No system technician action is required.