User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-608EXP-INTF (Expansion Interface Circuit Pack) 
10
23 (b) 0 None WNG OFF
125 (c) None MIN ON
131 (d) None MINOR/ 
WNG
2
OFF
257 (e) Any None MINOR/ 
WNG
2
OFF
513 (f) 5-7 None MAJ ON
769 113 Expansion Interface FOOF 
Query Test (#238)
WRN OFF test board PCSS r 1
770 Expansion Interface FOOF 
Query Test (#238
WRN OFF test board PCSS r 1
1025 Any Expansion Interface Control 
Channel Test (#316)
MAJ ON test board PCSS r 1
1281 Expansion Interface 
Neighbor Query Test (#237)
MINOR/ 
WNG
2
OFF test board PCSS r 1
1537 Expansion Interface 2-way 
Transmission Test (#241)
MAJ OFF test board PCSS r 4
1538 (g) None MIN ON
1793 Expansion Interface 
Lightwave Transceiver Loop 
Around Test (#242)
MAJ ON test board PCSS l r 1
2049 (h) Any Reset Test (#336) MIN ON reset board PCSS r 1
2305 (i) 118 None WRN OFF
2561
1
 (j) Any None MIN ON
2817
1
 (k) Any None MIN ON
3073
1
Any Expansion Interface Packet 
Interface Test (#589)
MIN OFF test board PCSS rep 3
3074
1
 (l) 2 Expansion Interface Packet 
Interface Test (#589)
MINOR/
WRN
2
OFF test board PCSS rep 3
3075
1
 (l) 1 Expansion Interface Packet 
Interface Test (#589)
MINOR/
WRN
2
OFF test board PCSS rep 3
3076
1
Expansion Interface Packet 
Interface Test (#589)
MINOR/
WRN
2
OFF test board PCSS rep 3
3330
1
 (m) Any None WRN ON
Table 10-208. Expansion Interface Circuit Pack Error Log Entries  — Continued
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
Continued on next page