User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-590ERR-LOG (Error Log) 
10
ERR-LOG (Error Log)
Functional Description
The ERR-LOG MO is responsible for the sanity of the Alarm Log, the Hardware 
Error Log, and the Software Error Log. If an inconsistency is detected in any one 
of these logs, all logs are re-initialized and a hardware error is logged against 
ERR-LOG indicating the time of inconsistency. There are no tests and no alarms 
for the Error Log MO. This MO exists solely for the purpose of allowing errors to 
be logged against it.
Hardware Error Log Entries and Test to Clear 
Values
Notes:
a. This error indicates that an inconsistency was detected in either the Alarm 
Log, the Hardware Error Log, or the Software Error Log. To recover from 
this error, all of the logs were cleared and re-initialized. Any alarms that 
were active at the time of this error have been cleared. There is no 
associated test for this error. If the error persists, escalate the problem.
The Aux data value indicates when the inconsistency was found:
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to 
the appropriate test description and follow the recommended procedures.
MO Name (in 
Alarm Log) Alarm Level
Initial Command to 
Run Full Name of MO
ERR-LOG none none Error Log
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
Any Any Any Any none
510 (a) Any none none none none
0 Found during a periodic audit of the Error Log
1 Found after an extended reboot
2 Found after a reboot
3 Found after a Reset System 3 (Cold_1)