Maintenance Object Repair Procedures 
Page 10-480DS1-BD (DS1 Interface Circuit Pack) 
10
Notes:
a. This error indicates that the circuit pack has stopped functioning or is not 
completely administered. The alarm is logged about 15 minutes after the 
circuit pack has been removed or 11 minutes after the SAKI Test (#53) 
fails.
To be completely administered, a DS1 circuit pack must meet all 3 of the 
following conditions:
1. Have an entry in the circuit plan via the change circuit pack 
command
2. Be administered via the add ds1 PCSS command
3. Be physically inserted in the appropriate slot
If the circuit pack has an entry in the circuit plan and either of the other two 
conditions are 
not
 met, a MINOR alarm is logged. To resolve the error 
either
1. Make sure all conditions for administration are met and that a 
functioning DS1 circuit pack is inserted in the correct slot.
2. Completely remove the DS1-BD from the system using the following 
steps:
a. Remove any administered DS1 trunks or access endpoints 
associated with the circuit pack from their trunk groups.
b. Execute the remove ds1 PCSS and change circuit pack 
PCSS commands.
If all the administration conditions are met for this circuit pack and the red 
LED is still on, follow the instructions for 
LED Alarms with Error Type 1
 in 
Chapter 7.
b. The DS1 Interface circuit pack has been busied out by a busy-out board 
PCSS command.
c. The DS1-BD circuit pack is not completely administered. A completely 
administered DS1-BD circuit pack should have an entry in the circuit plan 
via the change circuit pack command, should have been administered 
via the add ds1 PCSS command, and should have been inserted into the 
appropriate port slot.
d. The circuit pack in the slot does not match the type administered to that 
position. Either replace the circuit pack with one of the type administered, 
or use change circuit-pack to readminister the slot. This error may also 
indicate that the 24/32-channel selection on the DS1 administration form 
does not match the configuration of the circuit pack.
3. Off-board minor alarms on this maintenance object may be downgraded to Warning alarms based on 
the values used in the set options command.