DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-445DIG-LINE (Digital Line) 
10
Table 10-146. TEST #16 DIG-LINE Station Lamp Updates Test 
Error 
Code
Test 
Result Description/ Recommendation
ABORT Internal System Error
1. Retry the command at 1-minute intervals a maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1 ABORT This port may have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If 
this error type is present, then release the port via the release station 
<extension> command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
3 ABORT Station may be in ready-for-service or out-of-service state.
1. Use status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals a maximum of 5 times.
4. If the test continues to abort, escalate the problem.
1000 ABORT System resources required to run this test are not available. The port may 
be busy with a valid call. Use display port PCSSpp to determine the 
station extension or attendant number of the port. Use status station or 
status attendant to determine the service state of the port. If the service 
state indicates that the port is in use, then the port is unavailable for certain 
tests. (See Chapter 10, "Maintenance Commands and Trouble-Clearing 
Aids", for a full description of all possible states.) You must wait until the 
port is idle before retesting. Attendants are always in use (off-hook) if the 
handset is plugged in and the port is not busied out.
1. If the port status is idle, then retry the command at 1-minute intervals a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command 
(the display shows that the port is a TTI port) or the list config 
command (the display shows a t for the port).
2. If either list config or display port indicates that the port is 
not
 a TTI 
port, escalate the problem. If both commands indicate that the port is 
a TTI port, the abort is correct, and no action is necessary.
Continued on next page