DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-440DIG-LINE (Digital Line) 
10
Digital Line Electronic Power Feed/Positive 
Temperature Coefficient/PPF Test(#11)
For TN413, and TN754 vintage 13 or earlier, this is an Electronic Power Feed 
(EPF) restoral test. In this test, the processor requests that the EPF be turned on 
for a given port, and an attempt is made to turn on the power supply to the 
station. If no current is drawn, the station is probably not connected. If an 
overcurrent condition is sensed, there may be a short in the loop. A message is 
returned reporting that either the EPF was successfully turned on, or that an 
overcurrent condition was sensed. This test is repeated again 5 seconds later.
For TN754 vintage 14 or later, TN754B and TN2136 this is a Positive Temperature 
Coefficient (PTC) restoral test. In this test, the processor requests that the PTC be 
turned on for a given port, and an attempt is made to turn on the power supply to 
the station. If an overcurrent condition is sensed, there is probably a short on the 
power line that causing the PTC to open and disconnect the voice terminal. Since 
the PTC does not have self-restoral capability, the voice terminal must be 
manually unplugged for 30 seconds and then plugged back in to restore the 
PTC. A message is returned reporting that either the PTC was successfully 
turned on successfully with no problem or an overcurrent condition was sensed. 
This test is repeated again 5 seconds later.
TN2181 and TN2224 boards carry a Protected Power Feed (PPF) relays, one for 
each port. Therefore this will be a Protected Power Feed restoral test. The test 
procedure and its response is same as that of EPF. One of differences between 
EFP and PPF is that, if the port goes into a overcurrent state, PPF does not report 
this change of state because it is a transient state which will not last more than 
50ms. If the over current persists the power will be shut off automatically and an 
EPF_off_overcurrent message is sent uplink.
PASS The port is correctly using its allocated time slots.
1. To be sure that this is not an intermittent problem, repeat this test up to 
a maximum of 10 times to make sure it continues to pass.
2. If complaints persist, examine the station, connections, and wiring.
Table 10-143. TEST #9 Digital Line NPE Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page