Maintenance Object Repair Procedures 
Page 10-421DID-TRK (DID Trunk) 
10
0NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Check to ensure that the board translations are correct. Translate the 
board, if necessary.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board command. This should re-establish the linkage 
between the internal ID and the port.
Table 10-136. TEST #36 Port Audit Update Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page