User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-397DID-DS1 (DS1 DID Trunk) 
10
1003 ABORT The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present or some Tone 
Detectors may be out-of-service.
1. Look for TTR-LEV errors in the Error Log. If present, refer to TTR-LEV 
(TTR Level) Maintenance documentation.
2. Look for TONE-PT errors in the Error Log. If present, refer to TONE-PT 
(Tone Generator) Maintenance documentation.
3. If neither condition exists, retry the test at one-minute intervals a 
maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port was seized by a user for a valid call. Use the display port 
PCSSpp command to determine the trunk group/member number of the 
port. Use the status trunk command to determine the service state of the 
port. If the service state indicates that the port is in use, then the port is 
unavailable for certain tests. You must wait until the port is idle before 
retesting.
1. If the port status is idle, retry the command at 1 minute intervals for a 
maximum of 5 times.
2. If the test continues to abort, escalate the problem.
1020 ABORT The test did not run due to a previously existing error on the specific port 
or a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the previously existing error.
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a maximum of five times.
2. If the test continues to abort, escalate the problem.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack: 
1281—Loss of signal, 1793—Blue Alarm, 2049—Red Alarm, 2305—Yellow 
Alarm, 1537—Hyperactivity.
Look for the above error types in the Hardware Error Log and follow the 
procedures given in the appropriate DS1-BD or UDS1-BD maintenance 
documentation for the listed error types.
Table 10-129. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page










