Page 10-395DID-DS1 (DS1 DID Trunk) 
10
e. DS1 Interface circuit pack detects a hardware error. The Aux Data field 
contains the Error Type: 57474, rotary dial rate above 12 pulses per 
second; 57473, rotary dial rate below eight pulses per second. Escalate 
the error.
f. DS1 Interface circuit pack detects a hardware error. The Aux Data field 
contains the Error Type: 57392, no external release on PBX disconnect. 
Escalate the error.
g. DS1 Interface circuit pack detects a hardware error. The Aux Data field 
contains the Error Type: 57393, belated external release on PBX 
disconnect. Escalate the error.
h. DS1 Interface circuit pack is out-of-service. Look for DS1-BD errors in 
Hardware Error Log. Refer to the DS1-BD (DS1 Trunk Circuit Pack) 
Maintenance documentation for details.
i. Error Type 2305—This error indicates that a signaling change was 
detected by the PBX trunk circuit pack which is inconsistent with the 
present state of the trunk.
j. Port Audit and Update Test (#36) failed due to an internal system error. 
Enter status trunk command to verify the status of the trunk. If the trunk is 
out-of-service, then enter the release trunk command to put it back to 
in-service. Retry the test command. If the test continues to abort, then 
escalate the problem.
System Technician-Demanded Tests: 
Descriptions and Error Codes
Always investigate tests in the order they are presented in the table below when 
inspecting errors in the system. By clearing error codes associated with the 
NPE 
Crosstalk Test,
 for example, you may also clear errors generated from other tests 
in the testing sequence..
NPE Crosstalk Test (#6)
One or more NPEs reside on each circuit pack with a TDM Bus interface. The 
NPE controls port connectivity and gain, and provides conferencing functions on 
a per-port basis. The NPE Crosstalk Test verifies that this port’s NPE channel 
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence D/ND
1
NPE Crosstalk Test (#6) X ND
Conference Circuit Test (#7) X ND
Port Audit and Update Test (#36) X ND