User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-379DAT-LINE (Data Line) 
10
DAT-LINE (Data Line)
The TN726 Data Line circuit pack is a port circuit that provides connectivity from 
the system to asynchronous CPE having RS232-compatible serial interfaces. 
There are eight data lines (DAT-LINEs) on the Data Line circuit pack. If there are 
errors associated with the DT-LN-BD (Data Line Circuit Pack), refer to the 
XXX-BD (Common Port Circuit Pack) Maintenance documentation.
Data Lines are administered via the administration terminal add data-module 
command. The data module type is 
data-line
. The list data-module command 
lists all administered data modules in the system.
The TN750 Announcement circuit pack has one Data Line on it. The Data Line is 
used for saving and restoring announcements. For a description of this feature, 
refer to ANN-BD (Announcement Circuit Pack) Maintenance documentation. 
Also, if there are errors associated with the Announcement circuit pack, refer to 
the ANN-BD Maintenance documentation.
NOTE:
If the tests for the Data Line in question pass and there are still 
user-reported problems, there is probably an external problem. Test the 
ADU, following the procedures outlined in 
User Manual Z3A Asynchronous 
Data Unit
, 555-401-701. If the ADU appears to be working properly, check 
the external wiring and, finally, check the customer equipment.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier 
designation (for example, A, B, C, D, or E); and SS is the address of the slot in the carrier 
where the circuit pack is located (for example, 01, 02, ..., etc.).
MO Name (in 
Alarm Log)
Alarm 
Level Initial Command to Run
1
Full Name of MO
DAT-LINE MINOR test port PCSSpp l Data Line
DAT-LINE WARNING test port PCSSpp sh Data Line