User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-364DATA-CHL (Network Control Data Channel) 
10
2011 
2012 
2013 
2016 
2017 
2020 
2022 
2051
ABORT Refer to STBY-SPE (Standby SPE) Maintenance documentation for a 
description of these error codes.
40
41 
2000 
2003 
2004
FAIL In the case of Error Codes 40 and 41, the Remote Maintenance Loop Around 
Test failed because the data received over the connection did not match the 
data sent over the connection (data was corrupted). In the case of Error 
Codes 2000, 2003, and 2004, the Remote Maintenance Loop Around Test 
failed because the data looped over the connection was not received (data 
was lost).
However, because it involves two DATA-CHLs, the test’s failure is not 
sufficient to indict either one of the two DATA-CHLs as defective.
1. Check the dial plan to make sure that the extensions of the data channel 
are set up as local extensions rather than remote or UDP extensions.
2. Determine which of the DATA-CHLs is in use for some other function 
(that is, CDR Link, System Printer Link, Journal Printer Link, PMS Link, or 
secondary administration terminal connection) as described in the 
"Status of Network Control Data Channels" section.
3. Note the test results for Tests #110 and #111 in the Short Test Sequence 
for the target DATA-CHL and refer to Steps 4, 5, and/or 6 to determine 
the appropriate actions to take based on those results.
Table 10-117. TEST #109 Data Channel Remote Maintenance Loop Around Test  — Continued
Error 
Code
Test 
Result Description/Recommendation
Continued on next page