User manual
DEFINITY Enterprise Communications Server Release 6
Maintenance for R6vs/si 
555-230-127  
Issue 1
August 1997
Maintenance Object Repair Procedures 
Page 10-353DATA-CHL (Network Control Data Channel) 
10
If the DATA-CHL must be busied out in order to perform maintenance testing, the 
secondary administration terminal connection must be re-established by 
redialing the DATA-CHL.
CDR Links
1. Issue the status smdr-link command to see if an CDR Link has been 
established. If the Link State field is "Up," then the CDR Link may be using 
one of the Network Control Data Channels (DATA-CHLs).
2. Issue the display system features command and go to the CDR 
subsection on Page 2 of the resulting form. Note the values in the Primary 
Output Extension and Secondary Output Extension fields. If the values are 
extensions, then the CDR Link is using one of the Network Control Data 
Channels (DATA-CHLs).
3. For each of the extensions in the Primary Output Extension and Secondary 
Output Extension fields, issue the status data-module <ext> command 
using the extension. Note the value in the Connected Ports field of the 
resulting form. If there is a port value in the field, then the indicated port is 
a Network Control Data Channel (DATA-CHL).
4. Issue the list data-module command, locate each port indicated in the 
Connected Ports fields, and determine if that port has a "type" value of 
"netcon." If so, then there is an CDR Link over that DATA-CHL.
System Printer Links
1. Issue the status sp-link command to see if a System Printer Link has 
been established. If the Link State field is "Up," then the System Printer 
Link may be using one of the Network Control Data Channels 
(DATA-CHLs).
2. Issue the display system features command and go to the System 
Printer subsection on Page 2 of the resulting form. Note the values in the 
Primary Output Extension and Secondary Output Extension fields. If the 
values are extensions, then the System Printer Link is using one of the 
Network Control Data Channels (DATA-CHLs).
3. For each of the extensions in the Primary Output Extension and Secondary 
Output Extension fields, issue the status data-module <ext> command 
using the extension. Note the value in the Connected Ports field of the 
resulting form. If there is a port value in the field, then the indicated port is 
a Network Control Data Channel (DATA-CHL).
4. Issue the list data-module command, locate each port indicated in the 
Connected Ports fields, and determine if that port has a "type" value of 
"netcon." If so, then there is a System Printer Link over that DATA-CHL.