User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-54ANL-16-L (16-Port Neon Analog Line) 
10
1018 ABORT The test has been disabled via administration. The default for the ’Test’ 
field on the ’Station’ form is ’y’; thus, you may want to determine why this 
field has been set to ’n’ on this station (this may be due to the ringing 
application test 48, which can be customer or terminal disturbing).
1. To enable the test for the particular analog station being tested, enter 
change station extension and set the ‘Test?’ field on the station from 
'n' to 'y.'
2000 ABORT Response to the test request was not received within the allowable time 
period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at one-minute intervals a maximum of five times.
FAIL The port's battery feed chip is unable to supply sufficient power to the 
terminal equipment. This could be a marginal test, and the terminal 
equipment may be operating satisfactorily.
1. Retry the test at 1-minute intervals for a maximum of 5 times.
2. If the test continues to fail, determine whether the customer is 
experiencing problems on this line. Replace the circuit pack only if the 
customer is experiencing problems.
PASS The port’s battery feed chip is able to provide power to the station 
equipment to detect on-/off-hook, but may not be able to supply power for 
touch-tones. If touch-tones are inoperative on this station, then replace the 
circuit pack because this port is inoperative. User-reported troubles on 
this port should be investigated by using other port tests, by examining 
station wiring, or by examining the station.
0NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Check to ensure that the board translations are correct. Use the list 
config command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the 
busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command. This should re-establish the 
linkage between the internal ID and the port. If this is not the case, 
dispatch to check to ensure that there is a valid board inserted.
Table 10-22. TEST #35 Battery Feed Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page