User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-7ABRI-PORT (ASAI ISDN-BRI Port) 
10
ABRI-PORT (ASAI ISDN-BRI Port)
NOTE:
Refer to "BRI-PORT (ISDN-BRI Port), ABRI-PORT (ASAI ISDN-BRI 
Port)" for repair procedures.
1. Where P is the port network number (1 for PPN and 2 or 3 for EPN); C is the carrier designation 
(A, B, C, D, or E); and SS is the address of the slot in the carrier where the circuit pack is 
located (01, 02, ..., and so forth); and pp is the 2-digit port number (for example, 01).
2. The alarm level for ABRI ports may be administered using the set options command. The 
alarm level can be set independently for Off-Board and On-Board alarms to MAJOR for all 
ABRI ports in the system.
MO Name (in 
Alarm Log) Alarm Level Initial Command to Run
1
Full Name of MO
ABRI-PORT
2
MAJOR(b) test port PCSSpp l  ASAI ISDN-BRI Port
ABRI-PORT  MINOR test port PCSSpp l  ASAI ISDN-BRI Port