User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-659test spe-standby 
8
All maintenance resources busy; try again later
Output
The responses will be displayed on a test-by-test basis with one line of data 
displayed for each test result.
For the following output example the command entered was "test sp-link".
Feature Interactions
None.
test spe-standby
This command allows the technician to test the standby Switch Processing 
Element.
Synopsis
test spe-standby 
[ short | long ][ repeat number | clear ]
Port Not applicable. Will always be blank.
Maintenance Name The type of maintenance object that is being tested. This will 
always be "SYS-PRNT".
Alt. Name Not applicable. Will always be blank.
Test No The actual test that is being executed.
Result The result of the individual test - "PASS", "ABORT", "FAIL", "NO 
BOARD", "DISABLED", "EXTRA BD".
Error Code A system-generated number that tells why the test failed or 
aborted. A detailed list of the codes according to "Test No." is 
provided for each MO.
 test sp-link SPE A
 TEST RESULTS
 Port Maintenance Name Alt. Name Test No. Result Error Code
 SYS-PRNT 215 PASS
 SYS-PRNT 213 PASS
 Command Successfully Completed