User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-600test interface 
8
If the technician-entered carrier is not active, the following error message will be 
entered:
Board invalid
If the specified carrier/position processor interface circuit pack is not inserted, 
but the specified carrier is active, the following error message will be displayed:
No such MO’s lname/pname
If the command entered is in conflict with another currently executing command, 
then a message will be displayed showing the login id of the conflicting user and 
the conflicting command. The message is as follows:
’login id’:’command’ has a command conflict
If the standby is entering maintenance mode when this command is executed, 
then the following message is displayed:
Cannot interrupt Standby SPE while entering
maintenance mode; please try later
If the standby SPE is not refreshed when this command is executed, then the 
following message is displayed:
Standby SPE memory not refreshed; 
use the "refresh spe-standby" command.
If the standby SPE is not refreshed and the active SPE is hard selected via the 
SPE select switches when this command is executed, then the following 
message is displayed:
Active SPE locked via select switches; 
Standby SPE memory not refreshed
If the standby SPE is busy with another task, then the following message is 
displayed:
Standby SPE busy with another task; 
for information use "status system 1"
If the standby SPE is not available when this command is executed, then the 
following message is displayed:
Standby SPE not available;
for information use "status system 1"
If during the execution of a command a resource problem occurs that requires 
the user to restart the command, then the following message will be displayed:
Command resources busy;
Press CANCEL to clear, and then resubmit
If all of the available maintenance resources are currently in use, then the 
following message will be displayed:
All maintenance resources busy; try again later