Maintenance Commands and Trouble-Clearing Aids 
Page 8-592test hardware-group 
8
If no tests are available for the MOs in the specified hardware group the following 
message is displayed:
No tests available for MOs in the
specified hardware group
If the spe-interchange option was selected and the command was run from a 
non-PPNSAT the following message is displayed while the interchange takes 
place:
SPE interchange in progress, please wait
If the spe-interchange option was selected and the command was run from the 
PPNSAT, the interchange will be the last operation to run and then the SAT will be 
logged off as part of the interchange.
If an interchange cannot be performed the following message is displayed:
Cannot perform SPE interchange,
for information use ’status spe’
The responses to a "test hardware-group" command run in the foreground will be 
displayed on a test-by-test basis with one line of data displayed for each test 
result.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that has been tested.
Maintenance Name The type of maintenance object that has been tested.
Alt. Name The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xxx 
when the object is a private CO line, where xxx is the private CO 
line group number.