User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-570test ds1-loop 
8
Parameters
location A "location" represents the physical position of the 
board to be tested. For standard cabinets, a location is 
entered as "UUcSS" where "UU" represents the cabinet 
number, "c" represents the carrier, and "SS" represents 
the slot position. A single digit cabinet (1-3) may be 
entered with or without a leading zero (0).
cpe-loopback-jack-test-begin For TN464F or TN767E or later suffix DS1 boards, this 
will cause a long-duration loopback test to be setup 
through the Customer Premises Equipment (CPE) 
Loopback Jack. The command allows the user to 
specify a loop-up code for the CPE loopback jack if it 
differs from the default of 0x47F. This loop-up code is 
entered by specifying the number of bits in the loop-up 
code as well as the actual bit-pattern (in hexadecimal). 
The test will abort if the board has not been taken out of 
service via the "busyout" command.
far-csu-loopback-test-begin For TN464F or TN767E or later suffix DS1 boards, this 
will cause a long-duration loopback test to be setup 
through the far-end Channel Service Unit (CSU). The 
test will abort if the board has not been taken out of 
service via the "busyout" command.
one-way-span-test-begin For TN464F or TN767E or later suffix DS1 boards, this 
will begin execution of a long-duration one-way span 
test. The test will abort if the board has not been taken 
out of service via the "busyout" command.
end-loopback/span-test For TN464F or TN767E or later suffix DS1 boards, this 
parameter terminates long-duration one-way span and 
loopback testing.
inject-single-bit-error For TN464F or TN767E or later suffix DS1 boards, this 
parameter causes a single bit error to be sent within an 
active framed 3-in-24 test pattern used in long-duration 
loopback and span testing.
ds1/csu-loopback-tests For TN464F or TN767E or later suffix DS1 boards, this 
parameter will execute the following loopback tests: 
DS1 Board LoopBack, CSU Module Equipment 
LoopBack, and CSU Module Repeater LoopBack. 
These tests are performed sequentially for a short 
duration each, and individual PASS/FAIL/ABORT test 
results are reported following each test.