User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-544test alarms 
8
The following fields are displayed for the test results:
When errors are encountered preparing a particular object to be tested (not 
inserted, contention, etc.) the an error message will be displayed. This error 
message will be displayed in the TEST RESULTS data.
For the following output example, assume that only one alarm was in the alarm 
log and it is on the board in cabinet 1, carrier c, slot 7. The command that was 
entered was "test alarms" and the query form was left empty by just pressing 
"ENTER"
.
Port The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being tested.
Maintenance Name The type of maintenance object that is being tested.
Alt. Name The alternate means of identifying the maintenance object. This 
field contains the extension when the object is a station, and it 
contains xxx/yyy when the object is a trunk, where xxx is the trunk 
group number and yyy is the member number. It contains P/xxx 
when the object is a private CO line, where xxx is the private CO 
line group number.
Test No The actual test that is being executed.
Result An indicator as to whether the test failed, passed, aborted or no 
hardware was available (no board). If this field has conflict, this 
means that another user was testing this hardware. If this field has 
epn-down it means that the epn is inaccessible at this time.
Error Code A numerical description of why the test failed or was aborted.
test alarms       Page 1
 ALARM ENTRY
Port Maintenance On Alt Alarm Svc Ack? Date Alarm
 Name Brd? Name Type State 1 2 Alarmed Count
01C03 UDS1-BD n WARNING 03/06/16:48 1/4
 TEST RESULTS
Port Maintenance Name Alt. Name Test No. Result Error Code
01C03 UDS1-BD 138 NO BOARD
01C03 UDS1-BD 139 NO BOARD
01C03 UDS1-BD 140 NO BOARD
01C03 UDS1-BD 141 NO BOARD
01C03 UDS1-BD 142 NO BOARD
01C03 UDS1-BD 143 NO BOARD
01C03 UDS1-BD 144 NO BOARD
01C03 UDS1-BD 145 NO BOARD
01C03 UDS1-BD 146 NO BOARD
Testing completed for this object.
 press CANCEL to quit -- press NEXT PAGE to continue