Maintenance Commands and Trouble-Clearing Aids 
Page 8-509status system 
8
Output
For the following output example, the command that was entered is "status 
synchronization".
Feature Interactions
None.
status system
This command displays the status, mode, and operational attributes of the 
SPE(s), TDM and Packet busses, tone-clock circuit pack(s), expansion interface 
links (exp-links), and emergency transfer switch of a single cabinets or all 
cabinets in the system.
Stratum Level This is the synchronization stratum level, either a "3" 
or "4."
Maintenance Name: Either "TONE-BD," "DS1-BD," or "STRAT-3."
Physical Location The board location of the selected DS1 or tone-clock 
circuit pack. This includes the cabinet-carrier-slot for 
a DS1 or the cabinet-carrier for a tone-clock.
Switching Capability Whether the on-line reference for synchronization can 
be switched. "Enabled" and "Disabled" are used to 
describe the current capacity for reference switching.
Excessive Reference Switching This field gives a high level description of how many 
times the synchronization reference has been 
switched. If excessive reference switching is taking 
place (sync error 1793 is at threshold) this field 
displays "Yes," otherwise "No" is displayed.
 status synchronization
 SYNCHRONIZATION STATUS
 Stratum Level:4
 Maintenance Name: TONE-BD Physical Location: 01A
 Switching Capability: Enabled
 Excessive Reference Switching: No