User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-248monitor health 
8
Idle Idle indicates the proportion of the CPU which is currently available for 
use. This percentage is rounded to the nearest integer, therefore a 
percentage of 0 means that the occupancy is less than one half of a 
percent (e.g. an occupancy of 89.6% would be displayed as 90%).
Active SPE A or B is displayed to indicate the currently active processor complex. 
When the active processor complex is locked on-line via lock 
switching on DUPINT, the "lock" option will be displayed; otherwise, 
"auto" will be shown.
Duplicated? The duplication status of the SPE component is indicated. "y" indicates 
duplication and "n" indicates no duplication.
SPE Power The current source of power for the processor complex is indicated. 
The normal state is "commercial". When commercial power is not 
available, battery backup is in use and will be indicated by "backup".
Time Source The current timing source is displayed. The display values for this field 
vary according to the timing source selected. If the site has 
administered the optional Stratum-3 hardware, "external" will be 
displayed under normal operating conditions and "internal" will be 
displayed when an internal source, such as a tone clock, is used. 
Primary and secondary timing sources must be administered when 
using the Stratum-4 option. "primary" is displayed when the primary 
administered source is in use, and "secondary" is displayed when the 
administered secondary source is in use. When neither the primary or 
secondary sources are in use, "local" will be displayed.
# Logins The number of current users is displayed.
Cab The assigned cabinet number, ranging from 1 to the highest cabinet 
number in the system, is displayed on the screen.
Emerg Trans The current setting of the emergency transfer switch on the 
maintenance board is indicated for each cabinet. Five options are 
available: auto-on ("auto+" or "a+"), auto-off ("auto-" or "a-"), "on", "off", 
and "n.a.". Normally, the "auto+" or "auto-" option is enabled. In this 
state, emergency transfer will be activated automatically upon cabinet 
failure (The "+" indicates that emergency transfer is currently activated, 
while the "-" indicates that emergency transfer is currently not 
activated). When "on" is displayed, emergency transfer is automatically 
activated. The "off" option shows that the cabinet is prevented from 
activating emergency transfer. In a system equipped with duplicated 
SPEs, the switch settings for both processors of the PPN (cabinet 1) 
will be displayed. In this case, "auto+" will be abbreviated "a+", "auto-" 
will be abbreviated "a-", and "off" will be abbreviated as "of". "on" will 
not be changed. If "n.a." is displayed, the emergency transfer switch 
setting is not available.
Mj The individual number of major alarms associated with the cabinet is 
indicated. An asterisk is used to fill the field when the number exceeds 
99.