User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123 
Issue 1
April 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-62change system-parameters maintenance 
8
Packet Bus 
Activated
Enables the system Packet Bus. 
If this field is set to ‘‘yes'', then maintenance software assumes that 
there is a Packet Control circuit pack installed in the system. The 
packet endpoints (for example, ASAI, and/or BRI) may be 
administered, and maintenance testing runs on both the Packet 
Control circuit pack and on the Packet Bus (This field should be set to 
“yes” after a packet control circuit pack is installed.). If a Packet 
Control circuit pack is not installed in the system, then a major alarm 
is raised against the PKT-CTRL MO. 
This field can only be changed from ‘‘yes'' to ‘‘no'' if there are no 
packet endpoints administered, thus ensuring that there can be no 
packet endpoints administered if the packet bus is not activated. 
This field should be set to “yes” after a Packet Control circuit pack is 
installed.
If a Packet Control circuit pack is not installed, then this field should 
be set to ‘‘no'' (the only exception is when setting up translations for a 
system for which not all of the required hardware is available). (no)
Customer 
Access to 
INADS Port
Provides the capability to prohibit access to system administration and 
maintenance interface, via the INADS port when using customer login 
ID’s. This field can only be activated by Lucent Technologies services 
through system-parameters maintenance administration.(no)
Repeat Dial 
Interval 
(MMS)
Indicates the number of minutes that the system must wait before 
attempting another call origination to an OSS. This timer is triggered by 
the lack of a far-end acknowledgment.