FAIL The test failed because no neon current was detected.
1. Determine if there is a TN755 or TN752 power unit 
circuit pack installed in the same carrier as the 
TN746 or TN769 analog line circuit pack that failed 
the test. Look for the failure of test 220 on other 
TN746 or TN769 circuit packs in the carrier. If test 
220 fails on the other circuit packs, replace the 
TN755 or TN752 power unit circuit pack.
2. Retry the command again.
3. If the test continues to fail, replace the circuit pack.
4. Retry the command again.
5. If the test continues to fail, escalate the problem.
PASS This circuit pack is a TN746 or TN769 Analog Line 
circuit pack and the neon current is detected. This test 
also returns PASS for circuit packs that are not TN746 or 
TN769 circuit packs, but the test is not run on the circuit 
pack and the results of this test can be ignored.
any NO 
BOARD
This is normal if the test is being done when (a) the 
circuit pack is not physically in the system or (b) the 
system is booting up. Otherwise, there is some 
inconsistency between the physical configuration and 
the data kept in the system.
1. Verify that the circuit pack is physically in the 
system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at one-minute intervals for a 
maximum of five times.
4. If the test continues to return NO BOARD, escalate 
the problem.
Table 10-496. TEST #220 Neon Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page