Page 10-1680XXX-BD (Common Port Circuit Pack) 
10
Neon Test (#220)
This test checks the voltage required to light the neon lamp on an analog 
terminal. A relay connects a 150V DC source from the backplane of the circuit 
pack onto the voltage bus, and another relay connects a 2K shunt from the bus 
to ground. Current in the line is then monitored to determine if the voltage is 
present.
The neon test runs only for TN746 and TN769 Analog circuit packs. If the circuit 
pack is not a TN746 or TN769, the test returns PASS, but there is no testing done 
to the circuit pack.
any NO 
BOARD
This is normal if the test is being done when (a) the 
circuit pack is not physically in the system or (b) the 
system is booting up. Otherwise, there is some 
inconsistency between the physical configuration and 
the data kept in the system.
1. Verify that the circuit pack is physically in the 
system.
2. Verify that the system is not in a stage of booting up.
3. Retry the command at one-minute intervals for a 
maximum of five times.
4. If the test continues to return NO BOARD, escalate 
the problem.