Maintenance Object Repair Procedures 
Page 10-1679XXX-BD (Common Port Circuit Pack) 
10
This test is executed as part of the long test sequence only for the Tone-Clock 
circuit pack and DS1 interface circuit packs. All other common circuit packs can 
be reset via the reset board PCSS command. The reset command executes this 
test.
Table 10-495. TEST #53 SAKI Sanity Test 
Error 
Code
Test 
Result Description/ Recommendation
none ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1005 ABORT Wrong circuit pack configuration to run this test. This 
error applies only to DS1 interface circuit packs. It 
means the DS1 interface circuit pack is providing timing 
for the system and, therefore, it cannot be reset without 
major system disruptions.
1. If the circuit pack needs to be reset, set 
synchronization to another DS1 interface circuit 
pack or the Tone-Clock circuit pack and try again. 
Refer to SYNC (Synchronization) Maintenance 
documentation.
1015 ABORT Port is not out-of-service.
1. Busy out the circuit pack.
2. Execute command again.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
1 FAIL The circuit pack failed to reset.
2 FAIL The circuit pack failed to restart.
1. Execute command again.
2. If the problem persists, replace the circuit pack.
PASS The circuit pack initializes correctly.
1. Run the Short Test Sequence.
Continued on next page