Maintenance Object Repair Procedures 
Page 10-1674XXX-BD (Common Port Circuit Pack) 
10
Table 10-492. TEST #50 NPE Audit Test 
Error 
Code Test Result Description/ Recommendation
none or 
2100
ABORT System resources required for this test are not 
available.
1019 ABORT Test already in progress.
FAIL Internal System Error.
1. Retry the command at one-minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the 
problem.
PASS The circuit pack’s NPEs have been updated with 
their translation.
EXTRA BD Certain circuit packs have limitations on how 
many circuit packs can be in the system or port 
network such as the Maintenance/Test circuit 
pack (TN771B or TN771C), the Tone Detector 
circuit pack (TN748B, TN748C or TN748D) and 
the Call Classifier (TN744). The Maintenance/Test 
circuit pack allows only one circuit pack per port 
network. The Tone Detector and Call Classifier 
allow only 10 circuit packs in each system. All 
additional circuit packs return EXTRA-BD and 
should be removed.
any NO BOARD This is normal if the test is being done when (a) 
the circuit pack is not physically in the system or 
(b) the system is booting up. Otherwise, there is 
some inconsistency between the physical 
configuration and the data kept in the system.
1. Verify that the circuit pack is physically in the 
system.
2. Verify that the system is not in a stage of 
booting up.
3. Retry the command at one-minute intervals for 
a maximum of five times.
4. If the test continues to return NO BOARD, 
escalate the problem.
Continued on next page