User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1670XXX-BD (Common Port Circuit Pack) 
10
Hardware Error Log Entries and Test to Clear 
Values
1. Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the appropriate 
test description and follow the recommended procedures.
2. G3iV1-1.286 or G3iV2-386 only
Common Port Circuit Pack Maintenance Error Log Entries
Error 
Type
Aux 
Data Associated Test
Alarm 
Level
On/Off 
Board Test to Clear Value
0
1
0 Any Any Any test board PCSS sh r 1
1(a) 0 Circuit pack 
removed or SAKI 
Sanity Test (#53)
MINOR ON
18(b) 0 busyout board 
PCSS
WARNING OFF release board PCSS
23(c) 0 None WARNING OFF
36 (d) 4368 none
125 (e) None MINOR ON
217
2
 (f) 0 None WARNING ON
257 65535 Control Channel 
Test (#52)
MINOR ON test board PCSS sh r 20
257 (g) Any None
267 (f) 0 None WARNING ON
513 (h) Any None MINOR ON test board PCSS sh
769 (i) 4358 None
1025 (j) 4363 NPE Audit Test 
(#50)
test board PCSS l r 20
1281 (k) Ringing Application 
Test (#51)
MINOR ON test board PCSS r 2
1538 (l) Any None WARNING/ 
MINOR
ON
1793 (m) Neon Test (#220) MINOR ON test board PCSS r 2
3840 (n) Any None
3999 (o) Any None