User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1662WAE-PORT (Wideband Access Endpoint Port) 
10
1003 ABORT The system could not allocate a tone receiver for the 
test. The system may be oversized for the number of 
Tone Detectors present, or some Tone Detectors may 
be out-of-service. The list measurement tone-receiver 
command displays information on the system’s tone 
receivers.
1. Look for TTR-LEV errors in the Error Log. If errors are 
present, refer to TTR-LEV Maintenance 
documentation.
2. Look for TONE-PT errors in the Error Log. If errors 
are present, refer to TONE-PT Maintenance 
documentation.
3. If neither condition exists, retry the test at one minute 
intervals a maximum of five times.
4. If the test continues to abort, escalate the problem.
1004 ABORT The port has been seized by a user for a valid call. Use 
the status access-endpoint <extension> command to 
determine when the port is available for testing. The port 
is available when it is in the in-service/idle state.
1. Retry the command at one minute intervals a 
maximum of five times.
2. If the test continues to abort, and if the port is not in 
use, escalate the problem.
1020 ABORT The test did not run due either to a previously existing 
error on the specific port or to a more general circuit 
pack error.
1. Examine the Error Log for existing errors against this 
port or the circuit pack, and attempt to diagnose the 
already existing error.
2000 ABORT Response to the test request was not received within the 
allowable time period.
2100 ABORT System resources required for this test are not available.
1. Retry the command at one minute intervals a 
maximum of five times.
2. If the test continues to abort, escalate the problem.
Table 10-488. TEST #6 NPE Crosstalk Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page