User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1624UDS1-BD (UDS1 Interface Circuit Pack) 
10
1950 ABORT Another loopback/span test is already executing on the 
DS1 board or the board is in a network requested 
loopback mode (Line loopback or Payload loopback). 
The hardware error log will indicate whether a Customer 
Loopback Jack Test, Far CSU Loopback Test, or the 
One-Way Span Test is executing or if the board is in line 
loopback or payload loopback mode. Only one 
long-duration loopback/span test can be active at a 
given time. Thus, if a loopback/span test is already 
active, that test must be terminated via the 
test ds1-loop 
PCSS end-loopback/span-test
 command in order to 
execute this test.
Table 10-474. TEST #1214 One-Way Span Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page