User Guide
DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si 
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures 
Page 10-1610UDS1-BD (UDS1 Interface Circuit Pack) 
10
CPE Loopback Jack Test (#1212)
This test is destructive.
  FAIL UDS1 Interface circuit pack failed the CSU Repeater 
Loopback Test. 
1. Retry the 
test ds1-loop PCSS 
ds1/csu-loopback-tests
 command.
2. If the RLB test continues to fail, and the CSU 
Equipment Loopback Test (#1210) passed, then 
replace the CSU Module.
  PASS The RLB test executed successfully. The test pattern 
was transmitted and received successfully over the 
connection from the TN464F DS1 board to the far-edge 
of the 120A1 CSU Module.
0NO 
BOARD
The test could not relate the internal ID to the port (no 
board). This could be due to incorrect translations, no 
board is inserted, an incorrect board is inserted, or an 
insane board is inserted.
1. Ensure that the board translations are correct. 
Execute the add ds1 PCSS command to administer 
the UDS1 interface if it is not already administered.
2. If the board was already administered correctly, 
check the error log to determine whether the board 
is hyperactive. If this is the case, the board is shut 
down. Reseating the board will re-initialize the 
board.
3. If the board was found to be correctly inserted in 
step 1, then issue the busyout board command.
4. Issue the reset board command.
5. Issue the release busy board command.
6. Issue the test board long command.
This should re-establish the linkage between the internal 
ID and the port.
Table 10-471. TEST #1211 CSU Repeater Loopback Test — Continued
Error 
Code
Test 
Result Description/ Recommendation
Continued on next page